The Promoting Interoperability (PI) Program originally was known as the Meaningful Use program and began in 2009. The program was initiated to get hospitals up and running with their Electronic Health Record (EHR) systems. Hospitals could receive incentive money for successfully proving (attesting) that they were using their EHR in a meaningful way. In 2018, the program got a name change and an overhaul. Now, there is no incentive money to earn, but there is a penalty if you don't complete your requirements.
On that note, let's dive right in and review your 2023 Promoting Interoperability requirements.
Below is a summary of the major changes to PI requirements for the 2023 reporting year.
Additionally, all hospitals and Critical Access Hospitals are required to use CEHRT that has been updated to meet 2015 Edition Cures Update criteria.
There are four categories of measures you must submit in the PI program. CMS calls these objectives. You must report certain measures within each category (outlined below). Based on what you submit for these measures you will be awarded points. You must score a minimum of 60 points to satisfy your PI requirements.
Objective |
Measure |
Maximum Points |
Required/ |
Electronic Prescribing |
ePrescribing |
10 |
Required |
Query PDMP |
10 |
Required |
|
Health Information Exchange |
Sending Health Information |
15 |
Required to choose 1 of 3 options |
Receiving and Reconciling |
15 |
||
HIE Bi-Directional Exchange |
30 |
||
Enable Exchange under TEFCA |
30 |
||
Provider to Patient Exchange |
Provide Patients Electronic Access to Health Information |
25 |
Required |
Public Health and Clinical Data Exchange |
Syndromic Surveillance |
25 |
Syndromic, Immunization, Labs and ECR, Required |
Immunization Registry |
|||
Electronic Case Reporting |
|||
Electronic Reportable Labs |
|||
Antimicrobial Use & |
|||
Public Health Registry |
5 Bonus points for |
Optional |
|
Clinical Data Registry |
Requirement: You must report 2 measures in this category (possible 20 points).
Measure Description: For at least one hospital discharge, medication orders for permissible prescriptions are transmitted electronically using CEHRT.
Denominator: The number of new or changed prescriptions written for drugs requiring a prescription for patients discharged during the reporting period.(Does not include controlled substances.)
Numerator: The number of prescriptions in the denominator generated and transmitted electronically.
Exclusion: If you do not have an internal pharmacy that can accept electronic prescriptions and no pharmacies accepting electronic prescriptions within 10 miles at the start of the reporting period.
Reporting Period: Any continuous 90-day period within the calendar year.
Scoring:
Measure Description: For at least one Schedule II opioid or Schedule III or IV drug electronically prescribed during the reporting period, you must use data from CEHRT to conduct a query of a PDMP for prescription drug history.
Exclusions:
Reporting Period: Any continuous 90-day period within the calendar year.
Scoring:
Requirement: Hospitals now have 3 reporting options to meet this objective.
MEASURE 1: Support Electronic Referral Loops by Sending Health Information
Measure Description: For at least one transition of care or referral, (e.g. you transition or refer your patient to another setting of care or provider of care) you must (1) create a summary of care record using CEHRT; and (2) electronically exchanges the summary of care record.
Denominator: The number of transitions of care and referrals during the reporting period for which the hospital or Emergency Department (ED) was the transitioning or referring provider.
Numerator: The number of transitions of care and referrals in the denominator where a summary of care record was created using CEHRT and exchanged electronically.
Exclusion: None
Reporting Period: Any continuous 90-day period within the calendar year.
Scoring:
MEASURE 2: Support Electronic Referral Loops by Receiving and Reconciling Health Information
Measure Description: For at least one electronic summary of care record received using CEHRT for patient encounters during the reporting period for which your hospital was the receiving party of a transition of care or referral.
OR for patient encounters for which you have never before encountered the patient, you conducted clinical information reconciliation for medication, medication allergy, and current problem list using CEHRT.
Denominator: The number of electronic summary of care records received using CEHRT for patient encounters during the reporting period in which your hospital has never before encountered the patient.
Numerator: The number of electronic summary of care records in the denominator for which clinical information reconciliation is completed using CEHRT for the following three clinical information sets: (1) Medication – Review of the patient’s medication, including the name, dosage, frequency, and route of each mediation; (2) Medication Allergy – Review of the patient’s known medication allergies; and (3) Current Problem List – Review of the patient’s current and active diagnoses.
Exclusion: None
Reporting Period: Any continuous 90-day period within the calendar year.
Scoring:
Measure Description: You must attest that you engage in bi-directional exchange with a Health Information Exchange (HIE) to support transitions of care. You are attesting to the following statements:
Exclusion: None
Reporting Period: Any continuous 90-day period within the calendar year.
Scoring:
Measure Description: Read more about TEFCA here. You are attesting to the following statements:
Exclusion: None
Reporting Period: Any continuous 90-day period within the calendar year.
Scoring:
Requirement: You must report 1 measure in this category (possible 25 points).
Measure Description: For at least one patient discharged from your hospital or ED:
Denominator: The number of unique patients discharged from your hospital or ED during the reporting period.
Numerator: The number of patients in the denominator (or patient authorized representative) who are provided timely access to health information to view online, download and transmit to a third party and to access using an application of their choice.
Exclusion: None.
Reporting Period: Any continuous 90-day period within the calendar year.
Scoring:
Requirement: Report on all four measures under the Public Health and Clinical Data Exchange objective.
Measure Description: Your hospital is in active engagement with a public health agency to submit immunization data and receive immunization forecasts and histories from the public health immunization registry/immunization information system.
Exclusions:
Measure Description: Your hospital is in active engagement with a public health agency to submit syndromic surveillance data from an ED.
Exclusions:
Measure Description: Your hospital is in active engagement with a public health agency to submit case reporting of reportable conditions.
Exclusions:
Measure Description: Your hospital is in active engagement with a public health agency to submit ELR results.
Exclusions:
Reporting Period: Any continuous 90-day period within the calendar year.
Scoring:
If your hospital can claim an exclusion for three or fewer of the four required measures, you’ll receive the full 25 points if you report “yes” for one or more of the measures and claim applicable exclusions on the remaining measures. If you claim exclusions for all four required measures, the 25 points will be redistributed to the Provide Patients Electronic Access to their Health Information measure.
Bonus Measure: Public Health Registry Reporting
Measure description: Your hospital is in active engagement with a public health agency to submit data to public health registries.
Bonus Measure: Clinical Data Registry Reporting
Measure description: Your hospital is in active engagement with a public health agency to submit data to a clinical data registry.
Maximum points: 5 bonus points (for reporting on one of the two bonus measures).
Requirements:
Requirement:
The Safety Assurance Factors for EHR Resilience (SAFER) Guides were designed to help you optimize the safety and safe use of your EHRs. Your hospital must complete an assessment of all 9 SAFER Guides:
The good news is that, at this point, CMS is only tracking if hospitals are using the Guides. So, you can attest ‘Yes’ or ‘No’ without getting a penalty. If you’re new to the concept of SAFER Guides, we’ve created a detailed primer to help you understand each Guide and how to use them.
As a Medisolv client, your Clinical Quality Advisors are always on hand to help you translate CMS-speak into real, manageable steps you can take to make sure you’re not only meeting your Promoting Interoperability requirements but also achieving the requirements’ ultimate goal: better patient care through the power of more accessible data.
If you aren't a client, contact us now to schedule a time to chat, or check out our other resource guides for more info:
MEDISOLV CAN HELPAlong with award-winning software, each client receives a dedicated Clinical Quality Advisor that helps you with your technical and clinical needs. We consistently hear from our clients that the biggest differentiator between Medisolv and other vendors is the level of one-of-one support. Especially if you use an EHR vendor right now, you’ll notice a huge difference.
|